Independent control unit BAK-8 is designed for use in the general system of monitoring of refrigeration equipment and allows you to:
- take testimony from eight of the temperature sensor type PTC;
- continue the measurement of temperature values in case of power cuts throughout the system;
- store the values obtained in non-volatile memory in order to transfer the accumulated information to a central computer monitoring system at the time of the resumption of electricity supply;
|
|
Read more...
|
|
Phase switching unit (BKF-1) is designed for three-phase power line voltage control and for load switching in case of power supply voltage out of the established boundaries. |
|
Read more...
|
|
Signal concentrator KC4-32 is designed to collect and process digital information coming from the control devices such as DCC-XP, ES6-180, BASK, BUK-3 and transfer it to a personal computer. The concentrator can function as a standalone device, and as part of a network that includes several of the devices served by a personal computer. |
|
Read more...
|
Controller BUK-Atom is designed to control air-conditioning ATOM-250 Controller carries out:
- management conditioning compressor on the basis of on / off;
- evaporator fan control on the basis of on / off;
- control condenser fan speed to maintain the desired temperature of condensation;
- measurement of temperature at the inlet and outlet of the evaporator;
- measurement of temperature at the inlet and outlet of the condenser;
- measurement of pressure boiling (LP) and condensation (HP) of freon;
- condition monitoring sensors, high and low pressure freon;
- condition monitoring sensors, thermal and current protection of the compressor;
- condition monitoring sensor for thermal protection of the evaporator fan;
- condition monitoring sensor for thermal protection of the condenser fan;
- off air-conditioning system, fire protection team NPP;
- off air-conditioning system on command launch equipment unit step;
- control of three-phase supply voltage;
- calculation of partial and full-time fan of the evaporator and compressor;
- recovery efficiency air-conditioning supply at the interval;
- function "automatic inclusion of the reserve";
- initial delay and restart the compressor.
|
|
Read more...
|
|
Digital power main state analyzer (BOSS) is designed for the analysis of three-phase power supply network and disable the protected load (eg, compressor), in the event of network parameters beyond the normal operation. |
|
Read more...
|
|
Digital 16-channel dry contact state analyzer (BASK) is designed for collecting and processing information about the state of 16 normally-closed (NC) or normally open (NO) dry contacts located on the serviced units and facilities, and issuing appropriate messages as a built-in display and external device. |
|
Read more...
|
|
|
|
|
|